| |||
Interfaces and Methods - Schemas - FDT Specification - Quicklinks - Abbreviations | |||
FDTSERCOSScanIdentSchema |
Download Sercos Annex from FDT Group Homepage. FDTSERCOSScanIdentSchema"
xmlns="urn:schemas-microsoft-com:xml-data" xmlns:dt="urn:schemas-microsoft-com:datatypes" xmlns:sercosident="x-schema:FDTSERCOSIdentSchema.xml" xmlns:fdt="x-schema:FDTDataTypesSchema.xml" ><!-- Version of the Schema --> <AttributeType name="schemaVersion" dt:type="number" default="1.00" /> <AttributeType name="resultState" dt:type="enumeration" dt:values="provisional final error" /> <AttributeType name="configuredState" dt:type="enumeration" dt:values="configuredAndPhysicallyAvailable configuredAndNotPhysicallyAvailable availableButNotConfigured notApplicable" /> <!-- Definition of Elements --> <ElementType name="IdBusProtocol" content="empty" model="closed" > <attribute type="sercosident:busProtocol"
required="yes" /></ElementType> <ElementType name="IdAddress" content="empty" model="closed" > <!-- Comma-separated SERCOS addresses (0..511) --> <attribute type="sercosident:sercosAddresses"
required="yes" /></ElementType> <ElementType name="IdHardwareRevision" content="empty" model="closed" > <!-- IDN/S-0-1300.0.08 --> <attribute type="fdt:version"
required="yes" /></ElementType> <ElementType name="IdSoftwareRevision" content="empty" model="closed" > <!-- IDN/S-0-1300.0.09 --> <attribute type="fdt:version"
required="yes" /></ElementType> <ElementType name="IdManufacturer" content="empty" model="closed" > <!-- IDN/S-0-1300.0.03 --> <attribute type="fdt:manufacturerId"
required="no" /></ElementType> <ElementType name="IdTypeID" content="empty" model="closed" > <!-- IDN/S-0-1300.0.05 --> <attribute type="fdt:subDeviceType"
required="yes" /></ElementType> <ElementType name="IdDeviceName" content="empty" model="closed" > <!-- IDN/S-0-1300.0.04 --> <attribute type="fdt:name"
required="yes" /></ElementType> <ElementType name="ScanIdentification" content="eltOnly" model="closed" > <attribute type="configuredState"
required="no" /><element type="fdt:CommunicationError"
minOccurs="0" maxOccurs="1" /><element type="IdBusProtocol"
minOccurs="1" maxOccurs="1" /><element type="IdManufacturer"
minOccurs="1" maxOccurs="1" /><element type="IdTypeID"
minOccurs="1" maxOccurs="1" /><element type="IdAddress"
minOccurs="1" maxOccurs="1" /><element type="IdDeviceName"
minOccurs="0" maxOccurs="1" /><element type="IdHardwareRevision"
minOccurs="0" maxOccurs="1" /><element type="IdSoftwareRevision"
minOccurs="0" maxOccurs="1" /></ElementType> <ElementType name="ScanIdentifications" content="eltOnly" model="closed" > <attribute type="fdt:busCategory"
required="yes" /><attribute type="resultState"
required="yes" /><element type="ScanIdentification"
minOccurs="0" maxOccurs="*" /></ElementType> <ElementType name="FDT" content="eltOnly" model="closed" > <element type="ScanIdentifications"
minOccurs="1" maxOccurs="1" /></ElementType> </Schema> | ||
© by M&M Software GmbH, parts of this website taken from FDT Interface Specification Version 1.2.1, © by FDT Group, AISBL. This website is published for support of M&M products as granted in license conditions, chapter 2.1. Last updated 2015-02-05 15:18 Email: FDT Technical Support Line. | |||