| |||
Interfaces and Methods - Schemas - FDT Specification - Quicklinks - Abbreviations | |||
FDTInterbusScanIdentSchema | FDTInterbusScanIdentSchema" xmlns="urn:schemas-microsoft-com:xml-data" xmlns:dt="urn:schemas-microsoft-com:datatypes" xmlns:ibsident="x-schema:FDTInterbusIdentSchema.xml" xmlns:fdt="x-schema:FDTDataTypesSchema.xml" > <!-- Definition of Attributes --> <AttributeType name="schemaVersion" dt:type="number" default="1.21" /> <AttributeType name="resultState" dt:type="enumeration" dt:values="provisional final error" /> <AttributeType name="configuredState" dt:type="enumeration" dt:values="configuredAndPhysicallyAvailable configuredAndNotPhysicallyAvailable availableButNotConfigured notApplicable" /> <!-- Definition of elements --> <!-- --> <!-- IBS --> <!-- --> <ElementType name="IdAddress" content="empty" model="closed" > <attribute type="ibsident:systemNumber"
required="yes" /><attribute type="ibsident:segmentNumber"
required="yes" /><attribute type="ibsident:positionNumber"
required="yes" /></ElementType> <ElementType name="IdBusProtocol" content="empty" model="closed" > <attribute type="ibsident:busProtocol"
required="yes" /></ElementType> <ElementType name="TypeIDIBS" content="empty" model="closed" > <attribute type="ibsident:identCode"
required="yes" /><attribute type="ibsident:PALength"
required="yes" /><attribute type="ibsident:PDLength"
required="yes" /></ElementType> <!-- --> <!-- IBS PCP --> <!-- --> <ElementType name="IdTypeID" content="empty" model="closed" > <attribute type="ibsident:deviceName"
required="yes" /></ElementType> <ElementType name="IdManufacturer" content="empty" model="closed" > <attribute type="ibsident:manufacturerName"
required="yes" /></ElementType> <ElementType name="IdSoftwareRevision" content="empty" model="closed" > <attribute type="ibsident:firmwareRevision"
required="yes" /></ElementType> <ElementType name="IdentCode" content="empty" model="closed" > <attribute type="ibsident:identCode"
required="yes" /></ElementType> <ElementType name="ProcessLength" content="empty" model="closed" > <attribute type="ibsident:PDLength"
required="yes" /></ElementType> <ElementType name="ParamLength" content="empty" model="closed" > <attribute type="ibsident:PALength"
required="yes" /></ElementType> <!-- --> <!-- IBS Base Profile --> <!-- --> <ElementType name="IdHardwareRevision" content="empty" model="closed" > <attribute type="ibsident:hardwareRevision"
required="yes" /></ElementType> <ElementType name="OrderId" content="empty" model="closed" > <attribute type="ibsident:orderId"
required="yes" /></ElementType> <ElementType name="VendorId" content="empty" model="closed" > <attribute type="ibsident:vendorId"
required="yes" /></ElementType> <ElementType name="DeviceFamily" content="empty" model="closed" > <attribute type="ibsident:deviceFamily"
required="yes" /></ElementType> <ElementType name="PCPVersion" content="empty" model="closed" > <attribute type="ibsident:pcpVersion"
required="yes" /></ElementType> <ElementType name="CommProfile" content="empty" model="closed" > <attribute type="ibsident:commProfile"
required="yes" /></ElementType> <ElementType name="ManufacturerSpecificExtension" content="empty" model="closed" > <attribute type="ibsident:manufacturerSpecificExtension"
required="yes" /></ElementType> <ElementType name="ScanIdentification_IBS" content="eltOnly" model="closed" > <attribute type="configuredState"
required="no" /><!-- attributes with semantic meaning: --> <element type="fdt:CommunicationError"
minOccurs="0" maxOccurs="1" /><element type="IdAddress"
minOccurs="1" maxOccurs="1" /><element type="IdBusProtocol"
minOccurs="1" maxOccurs="1" /><element type="TypeIDIBS"
minOccurs="1" maxOccurs="1" /><!-- manufacturer specific extension, added in manufacturer specific identification --> <element type="ManufacturerSpecificExtension"
minOccurs="0" maxOccurs="1" /></ElementType> <ElementType name="ScanIdentification_IBS_PCP" content="eltOnly" model="closed" > <attribute type="configuredState"
required="no" /><!-- attributes with semantic meaning: --> <element type="fdt:CommunicationError"
minOccurs="0" maxOccurs="1" /><element type="IdAddress"
minOccurs="1" maxOccurs="1" /><element type="IdBusProtocol"
minOccurs="1" maxOccurs="1" /><element type="IdManufacturer"
minOccurs="1" maxOccurs="1" /><element type="IdTypeID"
minOccurs="1" maxOccurs="1" /><element type="IdSoftwareRevision"
minOccurs="1" maxOccurs="1" /><element type="IdentCode"
minOccurs="1" maxOccurs="1" /><element type="ProcessLength"
minOccurs="1" maxOccurs="1" /><element type="ParamLength"
minOccurs="1" maxOccurs="1" /><!-- manufacturer specific extension, added in manufacturer specific identification --> <element type="ManufacturerSpecificExtension"
minOccurs="0" maxOccurs="1" /></ElementType> <ElementType name="ScanIdentification_IBS_BASE_PROFILE" content="eltOnly" model="closed" > <attribute type="configuredState"
required="no" /><!-- attributes with semantic meaning: --> <element type="fdt:CommunicationError"
minOccurs="0" maxOccurs="1" /><element type="IdAddress"
minOccurs="1" maxOccurs="1" /><element type="IdBusProtocol"
minOccurs="1" maxOccurs="1" /><element type="IdManufacturer"
minOccurs="1" maxOccurs="1" /><element type="IdTypeID"
minOccurs="1" maxOccurs="1" /><element type="IdSoftwareRevision"
minOccurs="1" maxOccurs="1" /><element type="IdHardwareRevision"
minOccurs="1" maxOccurs="1" /><element type="IdentCode"
minOccurs="1" maxOccurs="1" /><element type="ProcessLength"
minOccurs="1" maxOccurs="1" /><element type="ParamLength"
minOccurs="1" maxOccurs="1" /><element type="OrderId"
minOccurs="1" maxOccurs="1" /><element type="VendorId"
minOccurs="1" maxOccurs="1" /><element type="DeviceFamily"
minOccurs="1" maxOccurs="1" /><element type="PCPVersion"
minOccurs="1" maxOccurs="1" /><element type="CommProfile"
minOccurs="1" maxOccurs="1" /><!-- manufacturer specific extension, added in manufacturer specific identification --> <element type="ManufacturerSpecificExtension"
minOccurs="0" maxOccurs="1" /></ElementType> <ElementType name="ScanIdentifications" content="eltOnly" model="closed" > <attribute type="fdt:busCategory"
required="yes" /><attribute type="resultState"
required="yes" /><group order="one" minOccurs="1" maxOccurs="*" > <element type="ScanIdentification_IBS"
minOccurs="0" maxOccurs="*" /><element type="ScanIdentification_IBS_PCP"
minOccurs="0" maxOccurs="*" /><element type="ScanIdentification_IBS_BASE_PROFILE"
minOccurs="0" maxOccurs="*" /></group> </ElementType> <ElementType name="FDT" content="eltOnly" model="closed" > <element type="ScanIdentifications"
minOccurs="1" maxOccurs="1" /></ElementType> </Schema> | ||
© by M&M Software GmbH, parts of this website taken from FDT Interface Specification Version 1.2.1, © by FDT Group, AISBL. This website is published for support of M&M products as granted in license conditions, chapter 2.1. Last updated 2015-02-05 15:18 Email: FDT Technical Support Line. | |||