M&M FDT 1.2.1 Online Specification
 DTMScanIdentSchema definition


Interfaces and Methods   -   Schemas   -   FDT Specification   -   Quicklinks   -   Abbreviations

12.33 DTMScanIdentSchema

Available since FDT 1.2.1.0

The protocol specific XML document provided by ScanResponse is to be transformed by the protocol specific XSLT. The transformation result must validate against DTMScanIdentSchema.

Available since FDT 1.2
Available since FDT 1.2.1
Available since FDT 1.2 and modified or extended in FDT 1.2.1
Specification description (mouse over)
dtmINSPECTOR related hint (mouse over)
Comment by M&M (mouse over)
Link to definition
<Schema name="DTMScanIdentSchema"   xmlns="urn:schemas-microsoft-com:xml-data" xmlns:dt="urn:schemas-microsoft-com:datatypes" xmlns:ident="x-schema:DTMIdentSchema.xml" xmlns:fdt="x-schema:FDTDataTypesSchema.xml" >
      <!-- Definition of Attributes -->
     <AttributeType name="resultState"   dt:type="enumeration" dt:values="provisional final error" />
     <AttributeType name="configuredState"   dt:type="enumeration" dt:values="configuredAndPhysicallyAvailable configuredAndNotPhysicallyAvailable availableButNotConfigured notApplicable" />
     <ElementType name="IdAddress"   content="empty" model="closed" >
          <attribute type="ident:value"   required="yes" />
          <attribute type="ident:protocolSpecificName"   required="yes" />
     </ElementType>
     <ElementType name="IdBusProtocol"   content="empty" model="closed" >
          <attribute type="ident:value"   required="yes" />
          <attribute type="ident:protocolSpecificName"   required="yes" />
     </ElementType>
     <ElementType name="IdBusProtocolVersion"   content="empty" model="closed" >
          <attribute type="ident:value"   required="no" />
          <attribute type="ident:protocolSpecificName"   required="yes" />
     </ElementType>
     <ElementType name="IdManufacturer"   content="empty" model="closed" >
          <attribute type="ident:value"   required="no" />
          <attribute type="ident:protocolSpecificName"   required="yes" />
     </ElementType>
     <ElementType name="IdTypeID"   content="empty" model="closed" >
          <attribute type="ident:value"   required="no" />
          <attribute type="ident:protocolSpecificName"   required="yes" />
     </ElementType>
     <ElementType name="IdSoftwareRevision"   content="empty" model="closed" >
          <attribute type="ident:value"   required="no" />
          <attribute type="ident:protocolSpecificName"   required="yes" />
     </ElementType>
     <ElementType name="IdDeviceTag"   content="empty" model="closed" >
          <attribute type="ident:value"   required="no" />
          <attribute type="ident:protocolSpecificName"   required="yes" />
     </ElementType>
     <ElementType name="IdHardwareRevision"   content="empty" model="closed" >
          <attribute type="ident:value"   required="no" />
          <attribute type="ident:protocolSpecificName"   required="yes" />
     </ElementType>
     <ElementType name="IdSerialNumber"   content="empty" model="closed" >
          <attribute type="ident:value"   required="no" />
          <attribute type="ident:protocolSpecificName"   required="yes" />
     </ElementType>
     <ElementType name="IdValue"   content="empty" model="closed" >
          <attribute type="ident:name"   required="yes" />
          <attribute type="ident:value"   required="yes" />
          <attribute type="ident:protocolSpecificName"   required="yes" />
     </ElementType>
     <ElementType name="IdValues"   content="eltOnly" model="closed" >
          <element type="IdValue"     minOccurs="0" maxOccurs="*" />
     </ElementType>
     <ElementType name="ScanIdentification"   content="eltOnly" model="closed" >
          <attribute type="configuredState"     required="no" />
          <element type="fdt:CommunicationError"   minOccurs="0" maxOccurs="1" />
          <element type="IdBusProtocol"     minOccurs="1" maxOccurs="1" />
          <element type="IdBusProtocolVersion"     minOccurs="1" maxOccurs="1" />
          <element type="IdAddress"     minOccurs="1" maxOccurs="1" />
          <element type="IdManufacturer"     minOccurs="1" maxOccurs="1" />
          <element type="IdTypeID"     minOccurs="1" maxOccurs="1" />
          <element type="IdSoftwareRevision"     minOccurs="1" maxOccurs="1" />
          <element type="IdHardwareRevision"     minOccurs="1" maxOccurs="1" />
          <element type="IdDeviceTag"     minOccurs="1" maxOccurs="1" />
          <element type="IdSerialNumber"     minOccurs="1" maxOccurs="1" />
          <element type="IdValues"     minOccurs="0" maxOccurs="1" />
     </ElementType>
     <ElementType name="ScanIdentifications"   content="eltOnly" model="closed" >
          <attribute type="fdt:busCategory"   required="yes" />
          <attribute type="resultState"     required="yes" />
          <element type="ScanIdentification"     minOccurs="0" maxOccurs="*" />
     </ElementType>
     <ElementType name="FDT" content="eltOnly" model="closed" >
          <element type="ScanIdentifications"
    minOccurs="1" maxOccurs="1" />
     </ElementType>
</Schema>

© by M&M Software GmbH, parts of this website taken from FDT Interface Specification Version 1.2.1, © by FDT Group, AISBL.
This website is published for support of M&M products as granted in license conditions, chapter 2.1.
Last updated 2015-02-05 15:17
Email: FDT Technical Support Line.