FDTModbusChannelParameterSchema | FDTModbusChannelParameterSchema
Download Modbus Annex from FDT Group Homepage. FDTModbusChannelParameterSchema"
xmlns="urn:schemas-microsoft-com:xml-data" xmlns:dt="urn:schemas-microsoft-com:datatypes" xmlns:fdt="x-schema:FDTDataTypesSchema.xml" xmlns:appId="x-schema:FDTApplicationIdSchema.xml" ><!-- FDT channel parameter schema V1.0 for Modbus protocol --> <!-- Definition of Attributes --> <AttributeType name="schemaVersion" dt:type="number" default="1.0" /> <AttributeType name="address" dt:type="ui2" /> <AttributeType name="modbusDataTypes" dt:type="enumeration" dt:values="coil discreteInput holdingRegister inputRegister" /> <AttributeType name="quantity" dt:type="ui2" /> <AttributeType name="protectedByChannelAssignment" dt:type="boolean" /> <AttributeType name="frameApplicationTag" dt:type="string" /> <AttributeType name="scaleValue" dt:type="string" /> <AttributeType name="statusChannel" dt:type="boolean" /> <AttributeType name="gatewayBusCategory" dt:type="uuid" /> <!-- All elements of the enumeration represent data types specified in IEC 61131-3 --> <AttributeType name="iecDataType" dt:type="enumeration" dt:values="BOOL SINT INT DINT LINT USINT UINT UDINT ULINT REAL LREAL TIME DATE TimeOfDay DateAndTime STRING BYTE WORD DWORD LWORD WSTRING" /> <!-- Definition of Elements --> <!-- Definition of Modbus access data element --> <ElementType name="ModbusAccessData" content="empty" model="closed" > <attribute type="fdt:nodeId"
/><!-- Starting address of the discrete input/coil/register --> <attribute type="address"
required="yes" /><!-- Type of data to be accessed --> <attribute type="modbusDataTypes"
required="yes" /><!-- Number of discrete inputs/coils/registers to be accessed --> <attribute type="quantity"
required="yes" /><!-- Access right for reading the Modbus data --> <attribute type="fdt:readAccess"
required="no" /><!-- Access right forwriting the Modbus data --> <attribute type="fdt:writeAccess"
required="no" /></ElementType> <!-- Definition of UnitScaling element --> <ElementType name="UnitScaling" content="empty" model="closed" > <attribute type="scaleValue"
required="yes" /></ElementType> <ElementType name="FDTChannel" content="eltOnly" order="seq" model="closed" > <attribute type="fdt:nodeId"
/><!-- Unique identifier for a device, module or channel --> <attribute type="fdt:tag"
required="yes" /><!-- Unique identifier for an element within the device namespace --> <attribute type="fdt:id"
required="yes" /><!-- Human readable description within the context of a element --> <attribute type="fdt:descriptor"
/><!-- TRUE if the channels is set to read only by the Frame Application --> <attribute type="protectedByChannelAssignment"
required="yes" /><!-- Standard FDT data type --> <attribute type="fdt:dataType"
required="yes" /><!-- Standard IEC 61131-3 data types --> <attribute type="iecDataType"
required="no" /><!-- Specifies a signal as input or output --> <attribute type="fdt:signalType"
required="yes" /><!-- Frame Application specific tag used for identification and navigation. --> <!-- The DTM should display this tag at channel specific user interfaces --> <attribute type="frameApplicationTag"
/><!-- The appearance and the functionality of a DTM user interface is controlled by the --> <!-- entry of the element applicationId, functionId, and operationPhase --> <attribute type="appId:applicationId"
/><!-- TODO SemanticIDs need to be defined --> <element type="fdt:SemanticInformation"
minOccurs="0" maxOccurs="*" /><!-- Collection of EnumerationEntry --> <element type="fdt:BitEnumeratorEntries"
minOccurs="0" maxOccurs="1" /><!-- Enumeration element --> <element type="fdt:EnumeratorEntries"
minOccurs="0" maxOccurs="1" /><!-- Current unit and the collection of possible units of a process variable --> <element type="fdt:Unit"
minOccurs="0" maxOccurs="1" /><!-- scale value for the grapical representation of the process value --> <element type="UnitScaling"
minOccurs="0" maxOccurs="1" /><!-- Address information needed to directly access the process data in the target device via Modbus --> <element type="ModbusAccessData"
minOccurs="0" maxOccurs="1" /><!-- Collection of alarms specified in FDT --> <element type="fdt:Alarms"
minOccurs="0" maxOccurs="1" /><!-- Collection of ranges specified in FDT, which describe the valid range of a process value --> <element type="fdt:Ranges"
minOccurs="0" maxOccurs="1" /><!-- Deadband is the amount of value changes that triggers for example new trend values. --> <element type="fdt:Deadband"
minOccurs="0" maxOccurs="1" /><!-- Describes a substitute value which is used in combination of the behavior of disturbed channel values --> <element type="fdt:SubstituteValue"
minOccurs="0" maxOccurs="1" /><!-- should be used if the data type is structured --> <element type="fdt:StructuredElements"
minOccurs="0" maxOccurs="1" /></ElementType> <ElementType name="FDTChannelType" content="eltOnly" order="seq" model="closed" > <attribute type="fdt:nodeId"
/><element type="fdt:VersionInformation"
/><!-- Unique identifier for a supported bus type like Profibus or HART according to the FDT specific CATID --> <attribute type="gatewayBusCategory"
required="no" /><!-- TRUE if the channel is for status information only --> <attribute type="statusChannel"
required="no" /></ElementType> <ElementType name="FDT" content="eltOnly" order="seq" model="closed" > <attribute type="schemaVersion"
/><attribute type="fdt:nodeId"
/><element type="FDTChannelType"
minOccurs="1" maxOccurs="1" /><element type="FDTChannel"
minOccurs="1" maxOccurs="1" /></ElementType> </Schema> | ||