Interfaces and Methods - Schemas - FDT Specification - Quicklinks - Abbreviations | |||
FDTModbusScanIdentSchema |
Download Modbus Annex from FDT Group Homepage. FDTModbusScanIdentSchema"
xmlns="urn:schemas-microsoft-com:xml-data" xmlns:dt="urn:schemas-microsoft-com:datatypes" xmlns:modbusident="x-schema:FDTModbusIdentSchema.xml" xmlns:fdt="x-schema:FDTDataTypesSchema.xml" xmlns:mb="x-schema:FDTModbusAddressSchema.xml" ><!-- FDT ScanIdent schema V1.0 for Modbus protocol --> <!-- The FDT DeviceTypeIdent schema defines the mapping of the Modbus identification objects --> <!-- to standard FDT identification elements --> <!-- The Modbus identification objects can be read with the standard Modbus service ReadDeviceIdentification --> <!-- The mapping of Modbus identification objects to FDT identification elements is divided into two categories: --> <!-- - Basic category: --> <!-- Mapping of mandatory Modbus identification objects to required (mandatory) FDT identification elements --> <!-- - Regular category: --> <!-- Mapping of optional Modbus identification objects to the optional FDT identification element IdValue --> <!-- Definition of general FDT attributes --> <AttributeType name="schemaVersion" dt:type="number" default="1.0" /> <AttributeType name="resultState" dt:type="enumeration" dt:values="provisional final error" /> <AttributeType name="configuredState" dt:type="enumeration" dt:values="configuredAndPhysicallyAvailable configuredAndNotPhysicallyAvailable availableButNotConfigured notApplicable" /> <!-- Definition of general FDT elements which contain the information about the applied protocol, --> <!-- the version of the protocol, the connection type and the address --> <ElementType name="IdBusProtocol" content="empty" model="closed" > <attribute type="modbusident:protocolName"
required="yes" /></ElementType> <ElementType name="IdAddress" content="eltOnly" model="closed" > <!-- Modbus specific addressing depending on connection type --> <group order="one" maxOccurs="1" minOccurs="1" > <element type="mb:ModbusSerial"
/><element type="mb:ModbusTCP"
/></group> </ElementType> <!-- Basic category: --> <!-- Mapping of Modbus identification elements required by the FDT DTMDeviceTypeIdent schema --> <!-- These elements represent all mandatory objects for Modbus device identification (basic category) --> <!-- Modbus identification object VendorName is mapped to FDT element IdManufacturer --> <ElementType name="IdManufacturer" content="empty" model="closed" > <attribute type="modbusident:vendorName"
required="yes" /></ElementType> <!-- Modbus identification object ProductCode is mapped to FDT element IdTypeID --> <ElementType name="IdTypeID" content="empty" model="closed" > <attribute type="modbusident:productCode"
required="yes" /></ElementType> <!-- Modbus identification object MajorMinorRevision is mapped to FDT element IdSoftwareRevision --> <ElementType name="IdSoftwareRevision" content="empty" model="closed" > <attribute type="modbusident:majorMinorRevision"
required="yes" /></ElementType> <!-- Regular category: --> <!-- Mapping of Modbus identification elements not required by the FDT DTMDeviceTypeIdent schema --> <!-- The information provided by each optional Modbus identification object (regular category) is mapped --> <!-- to the standard FDT identification element IdValues, which may occur several times --> <!-- The following optional Modbus identification objects are supported: --> <!-- VendorUrl Attribute name/Protocol specific name:"vendorUrl" --> <!-- ProductName Attribute name/Protocol specific name:"productName" --> <!-- ModelName Attribute name/Protocol specific name:"modelName" --> <!-- UserApplicationName Attribute name/Protocol specific name:"userApplicationName" --> <ElementType name="IdValue" content="empty" model="closed" > <attribute type="modbusident:name"
required="yes" /><attribute type="modbusident:value"
required="yes" /><attribute type="modbusident:protocolSpecificName"
required="yes" /></ElementType> <ElementType name="IdValues" content="eltOnly" model="closed" > <element type="IdValue"
minOccurs="0" maxOccurs="*" /></ElementType> <!-- FDT ScanIdentification element --> <ElementType name="ScanIdentification" content="eltOnly" model="closed" > <attribute type="configuredState"
required="no" /><element type="fdt:CommunicationError"
minOccurs="0" maxOccurs="1" /><element type="IdBusProtocol"
minOccurs="1" maxOccurs="1" /><element type="IdAddress"
minOccurs="1" maxOccurs="1" /><element type="IdManufacturer"
minOccurs="1" maxOccurs="1" /><element type="IdTypeID"
minOccurs="1" maxOccurs="1" /><element type="IdSoftwareRevision"
minOccurs="1" maxOccurs="1" /><element type="IdValues"
minOccurs="0" maxOccurs="1" /></ElementType> <ElementType name="ScanIdentifications" content="eltOnly" model="closed" > <attribute type="fdt:busCategory"
required="yes" /><attribute type="resultState"
required="yes" /><element type="ScanIdentification"
minOccurs="0" maxOccurs="*" /></ElementType> <ElementType name="FDT" content="eltOnly" model="closed" > <element type="ScanIdentifications"
minOccurs="1" maxOccurs="1" /></ElementType> </Schema> | ||
© by M&M Software GmbH, parts of this website taken from FDT Interface Specification Version 1.2.1, © by FDT Group, AISBL. This website is published for support of M&M products as granted in license conditions, chapter 2.1. Last updated 2015-02-05 15:18 Email: FDT Technical Support Line. | |||