Interfaces and Methods - Schemas - FDT Specification - Quicklinks - Abbreviations | |||
FDTProfinetIOScanIdentSchema |
Download ProfiNet IO Annex from FDT Group Homepage. FDTProfinetIOScanIdentSchema"
xmlns="urn:schemas-microsoft-com:xml-data" xmlns:dt="urn:schemas-microsoft-com:datatypes" xmlns:pnioident="x-schema:FDTProfinetIOIdentSchema.xml" xmlns:fdt="x-schema:FDTDataTypesSchema.xml" ><!-- Definition of Attributes --> <AttributeType name="schemaVersion" dt:type="number" default="1.00" /> <AttributeType name="resultState" dt:type="enumeration" dt:values="provisional final error" /> <AttributeType name="configuredState" dt:type="enumeration" dt:values="configuredAndPhysicallyAvailable configuredAndNotPhysicallyAvailable availableButNotConfigured notApplicable" /> <!-- DCP --> <ElementType name="IdBusProtocol" content="empty" model="closed" > <attribute type="pnioident:busProtocol"
required="yes" /></ElementType> <ElementType name="IdAddress" content="empty" model="closed" > <attribute type="pnioident:nameOfStation"
required="yes" /><attribute type="pnioident:ipAddress"
required="no" /><attribute type="pnioident:macAddress"
required="yes" /><attribute type="pnioident:ipSubnetMask"
required="no" /><attribute type="pnioident:ipDefaultGateway"
required="no" /></ElementType> <ElementType name="IdManufacturer" content="empty" model="closed" > <attribute type="fdt:manufacturerId"
required="yes" /></ElementType> <ElementType name="IdTypeID" content="empty" model="closed" > <attribute type="fdt:deviceTypeId"
required="yes" /></ElementType> <ElementType name="IdDeviceRole" content="empty" model="closed" > <attribute type="pnioident:deviceRole"
required="yes" /></ElementType> <ElementType name="ManufacturerSpecificExtension" content="empty" model="closed" > <attribute type="pnioident:manufacturerSpecificExtension"
required="yes" /></ElementType> <!-- I&M --> <ElementType name="IdOrder" content="empty" model="closed" > <attribute type="pnioident:orderId"
required="yes" /></ElementType> <ElementType name="IdSerialNumber" content="empty" model="closed" > <attribute type="pnioident:serialNumber"
required="yes" /></ElementType> <ElementType name="IdSoftwareRevision" content="empty" model="closed" > <attribute type="pnioident:softwareRevision"
required="yes" /></ElementType> <ElementType name="IdHardwareRevision" content="empty" model="closed" > <attribute type="pnioident:hardwareRevision"
required="yes" /></ElementType> <ElementType name="ProfileID" content="empty" model="closed" > <attribute type="pnioident:profileID"
required="yes" /></ElementType> <ElementType name="ProfileSpecificType" content="empty" model="closed" > <attribute type="pnioident:profileSpecificType"
required="yes" /></ElementType> <ElementType name="ScanIdentification_DCP" content="eltOnly" model="closed" > <attribute type="configuredState"
required="no" /><element type="fdt:CommunicationError"
minOccurs="0" maxOccurs="1" /><element type="IdBusProtocol"
minOccurs="1" maxOccurs="1" /><element type="IdAddress"
minOccurs="1" maxOccurs="1" /><element type="IdManufacturer"
minOccurs="1" maxOccurs="1" /><element type="IdTypeID"
minOccurs="1" maxOccurs="1" /><element type="IdDeviceRole"
minOccurs="1" maxOccurs="1" /><element type="ManufacturerSpecificExtension"
minOccurs="0" maxOccurs="1" /></ElementType> <ElementType name="ScanIdentification_IM" content="eltOnly" model="closed" > <attribute type="configuredState"
required="no" /><element type="fdt:CommunicationError"
minOccurs="0" maxOccurs="1" /><element type="IdBusProtocol"
minOccurs="1" maxOccurs="1" /><element type="IdAddress"
minOccurs="1" maxOccurs="1" /><element type="IdManufacturer"
minOccurs="1" maxOccurs="1" /><element type="IdTypeID"
minOccurs="1" maxOccurs="1" /><element type="IdDeviceRole"
minOccurs="1" maxOccurs="1" /><element type="ManufacturerSpecificExtension"
minOccurs="0" maxOccurs="1" /><element type="IdOrder"
minOccurs="1" maxOccurs="1" /><element type="IdSerialNumber"
minOccurs="1" maxOccurs="1" /><element type="IdSoftwareRevision"
minOccurs="1" maxOccurs="1" /><element type="IdHardwareRevision"
minOccurs="1" maxOccurs="1" /><element type="ProfileID"
minOccurs="1" maxOccurs="1" /><element type="ProfileSpecificType"
minOccurs="1" maxOccurs="1" /></ElementType> <ElementType name="ScanIdentifications" content="eltOnly" model="closed" > <attribute type="fdt:busCategory"
required="yes" /><attribute type="resultState"
required="yes" /><group order="one" minOccurs="1" maxOccurs="*" > <element type="ScanIdentification_DCP"
minOccurs="0" maxOccurs="*" /><element type="ScanIdentification_IM"
minOccurs="0" maxOccurs="*" /></group> </ElementType> <ElementType name="FDT" content="eltOnly" model="closed" > <element type="ScanIdentifications"
minOccurs="1" maxOccurs="1" /></ElementType> </Schema> | ||
© by M&M Software GmbH, parts of this website taken from FDT Interface Specification Version 1.2.1, © by FDT Group, AISBL. This website is published for support of M&M products as granted in license conditions, chapter 2.1. Last updated 2015-02-05 15:18 Email: FDT Technical Support Line. | |||