| |||
Interfaces and Methods - Schemas - FDT Specification - Quicklinks - Abbreviations | |||
FDTCCLinkScanIdentSchema |
Download CCLink Annex from FDT Group Homepage. FDTCCLinkScanIdentSchema"
xmlns="urn:schemas-microsoft-com:xml-data" xmlns:dt="urn:schemas-microsoft-com:datatypes" xmlns:fdt="x-schema:FDTDataTypesSchema.xml" xmlns:cclink="x-schema:DTMCCLinkDataTypeSchema.xml" xmlns:cclinkident="x-schema:FDTCCLinkIdentSchema.xml" ><!-- Definition of Attributes --> <AttributeType name="schemaVersion" dt:type="number" default="1.0" /> <AttributeType name="resultState" dt:type="enumeration" dt:values="provisional final error" /> <AttributeType name="configuredState" dt:type="enumeration" dt:values="configuredAndPhysicallyAvailable configuredAndNotPhysicallyAvailable availableButNotConfigured notApplicable" /> <!-- Definition of elements --> <ElementType name="IdAddress" content="empty" model="closed" > <attribute type="cclink:stationAddress"
required="yes" /></ElementType> <ElementType name="IdBusProtocol" content="empty" model="closed" > <attribute type="cclinkident:busProtocol"
required="yes" /></ElementType> <ElementType name="IdBusProtocolVersion" content="empty" model="closed" > <attribute type="cclink:protocolVersion"
required="yes" /></ElementType> <ElementType name="IdManufacturer" content="empty" model="closed" > <attribute type="cclink:vendorID"
required="yes" /></ElementType> <ElementType name="IdTypeID" content="empty" model="closed" > <attribute type="cclink:deviceModelType"
required="yes" /></ElementType> <ElementType name="IdSoftwareRevision" content="empty" model="closed" > <attribute type="cclinkident:softwareVersion"
required="yes" /></ElementType> <ElementType name="TotalNumOfIO" content="empty" model="closed" > <attribute type="cclinkident:totalNumOfIO"
required="yes" /></ElementType> <ElementType name="IOType" content="empty" model="closed" > <attribute type="cclinkident:ioType"
required="yes" /></ElementType> <ElementType name="NumOccupiedStations" content="empty" model="closed" > <attribute type="cclink:numOccupiedStations"
required="yes" /></ElementType> <ElementType name="StationType" content="empty" model="closed" > <attribute type="cclink:stationType"
required="yes" /></ElementType> <ElementType name="ManufacturerSpecificExtension" content="empty" model="closed" > <attribute type="cclinkident:manufacturerSpecificExtension"
required="yes" /></ElementType> <ElementType name="ScanIdentification_CCLink" content="eltOnly" model="closed" > <attribute type="configuredState"
required="no" /><element type="fdt:CommunicationError"
minOccurs="0" maxOccurs="1" /><element type="IdAddress"
minOccurs="1" maxOccurs="1" /><element type="IdBusProtocol"
minOccurs="1" maxOccurs="1" /><element type="IdBusProtocolVersion"
minOccurs="1" maxOccurs="1" /><element type="IdManufacturer"
minOccurs="1" maxOccurs="1" /><element type="IdTypeID"
minOccurs="1" maxOccurs="1" /><element type="IdSoftwareRevision"
minOccurs="1" maxOccurs="1" /><element type="StationType"
minOccurs="1" maxOccurs="1" /><element type="NumOccupiedStations"
minOccurs="1" maxOccurs="1" /><element type="IOType"
minOccurs="1" maxOccurs="1" /><element type="TotalNumOfIO"
minOccurs="1" maxOccurs="1" /><element type="ManufacturerSpecificExtension"
minOccurs="0" maxOccurs="1" /></ElementType> <ElementType name="ScanIdentifications" content="eltOnly" model="closed" > <attribute type="fdt:busCategory"
required="yes" /><attribute type="resultState"
required="yes" /><element type="ScanIdentification_CCLink"
minOccurs="0" maxOccurs="*" /></ElementType> <ElementType name="FDT" content="eltOnly" model="closed" > <attribute type="schemaVersion"
required="no" /><element type="ScanIdentifications"
minOccurs="1" maxOccurs="1" /></ElementType> </Schema> | ||
© by M&M Software GmbH, parts of this website taken from FDT Interface Specification Version 1.2.1, © by FDT Group, AISBL. This website is published for support of M&M products as granted in license conditions, chapter 2.1. Last updated 2015-02-05 15:17 Email: FDT Technical Support Line. | |||