Interfaces and Methods - Schemas - FDT Specification - Quicklinks - Abbreviations | |||
DtmFFSchema |
<!-- Definition of Attributes --> <AttributeType name="schemaVersion" dt:type="string" default="1.21" /> <!-- Definition of Elements --> <ElementType name="blockList" content="eltOnly" model="open" > <attribute type="fdt:nodeId"
required="no" /><element type="ffblock:BlockInformation"
minOccurs="0" maxOccurs="*" /></ElementType> <ElementType name="HSEDeviceInformation" content="eltOnly" model="closed" > <attribute type="fdt:nodeId"
required="no" /><attribute type="ffhse:stateSMK"
required="yes" /><attribute type="ffhse:repeatTimeHSE"
required="no" /><attribute type="ffhse:duplicateDetectionState"
required="no" /><!-- Operational IP address --> <attribute type="fftypes:ip"
required="no" /><!-- IP address of the device that responded. --> <element type="fftypes:IP"
minOccurs="1" maxOccurs="1" /><element type="ffhse:DeviceInformation"
minOccurs="1" maxOccurs="1" /><element type="ffhse:RedundancyInformation"
minOccurs="0" maxOccurs="1" /><element type="ffhse:VersionInformation"
minOccurs="0" maxOccurs="1" /></ElementType> <ElementType name="FoundationFieldbusH1Device" content="eltOnly" model="closed" > <attribute type="fdt:nodeId"
required="no" /><attribute type="fftypes:deviceType"
required="yes" /><!-- acts as PD-Tag --> <attribute type="fdt:tag"
required="yes" /><!-- Device ID --> <attribute type="fftypes:devID"
required="yes" /><element type="fftypes:VfdIdentification"
minOccurs="1" maxOccurs="*" /><element type="fftypes:DataLinkAddress"
minOccurs="1" maxOccurs="1" /></ElementType> <ElementType name="FoundationFieldbusHSEDevice" content="eltOnly" model="closed" > <attribute type="fdt:nodeId"
required="no" /><attribute type="fftypes:deviceType"
required="yes" /><!-- acts as PD-Tag --> <attribute type="fdt:tag"
required="yes" /><!-- Device ID --> <attribute type="fftypes:devID"
required="yes" /><element type="fftypes:VfdIdentification"
minOccurs="1" maxOccurs="*" /><element type="HSEDeviceInformation"
minOccurs="1" maxOccurs="1" /><!-- H1 device - nodeId contains node address HSE device - linkId = 0 nodeId = 0 selector = 2 --> <element type="fftypes:DataLinkAddress"
minOccurs="1" maxOccurs="1" /></ElementType> </Schema> | ||
© by M&M Software GmbH, parts of this website taken from FDT Interface Specification Version 1.2.1, © by FDT Group, AISBL. This website is published for support of M&M products as granted in license conditions, chapter 2.1. Last updated 2015-02-05 15:17 Email: FDT Technical Support Line. | |||