M&M FDT 1.2.1 Online Specification
 FDTCIPChannelParameterSchema definition


Interfaces and Methods   -   Schemas   -   FDT Specification   -   Quicklinks   -   Abbreviations

FDTCIPChannelParameterSchema

Available since CIP Annex for FDT 1.2.1

Download CIP Annex from FDT Group Homepage.

Available since FDT 1.2
Available since FDT 1.2.1
Available since FDT 1.2 and modified or extended in FDT 1.2.1
Specification description (mouse over)
dtmINSPECTOR related hint (mouse over)
Comment by M&M (mouse over)
Link to definition
<Schema name="FDTCIPChannelParameterSchema"   xmlns="urn:schemas-microsoft-com:xml-data" xmlns:dt="urn:schemas-microsoft-com:datatypes" xmlns:fdt="x-schema:FDTDataTypesSchema.xml" xmlns:cip="x-schema:DTMCIPDataTypeSchema.xml" xmlns:fdtsystag="DTMSystemTagListSchema.xml" >
      <!-- Version of the Schema -->
     <AttributeType name="schemaVersion" dt:type="number" default="1.0" />
      <!-- Definition of Attributes -->
     <AttributeType name="assemblySize"
dt:type="ui1" />
     <AttributeType name="memberPosition"
dt:type="ui4" />
     <AttributeType name="memberSize"
dt:type="ui4" />
     <AttributeType name="frameApplicationTag"
dt:type="string" />
     <AttributeType name="gatewayBusCategory"
dt:type="uuid" />
     <AttributeType name="protectedByChannelAssignment"
dt:type="boolean" />
     <AttributeType name="helpMessage"
dt:type="string" />
      <!-- Definition of Elements -->
     <ElementType name="AssemblyMemberReference"
content="empty" model="closed" >
          <attribute type="fdt:nodeId"
  required="no" />
          <attribute type="fdt:idref"   required="yes" />
          <attribute type="cip:bitOffset"   required="no" />
     </ElementType>
     <ElementType name="ChannelReference" >
          <attribute type="fdt:nodeId"
  required="no" />
          <attribute type="cip:bitOffset"   required="yes" />
          <element type="fdt:ChannelReference"   />
          <element type="cip:CIPObjectAddress"   minOccurs="1" maxOccurs="1" />
     </ElementType>
     <ElementType name="AssemblyMember" content="eltOnly" model="closed" >
           <!-- could be: a non-displayed, displayed parameters or assemblies -->
          <attribute type="fdt:nodeId"
  required="no" />
          <attribute type="memberPosition"   required="yes" />
          <attribute type="memberSize"   required="yes" />
          <group order="one" minOccurs="1" maxOccurs="1" >
               <element type="AssemblyMemberReference"   minOccurs="0" maxOccurs="1" />
               <element type="ChannelReference"   minOccurs="0" maxOccurs="1" />
               <element type="cip:CIPObjectAddress"   minOccurs="1" maxOccurs="1" />
               <element type="cip:Constant"   minOccurs="1" maxOccurs="1" />
          </group>
     </ElementType>
     <ElementType name="AssemblyMembers" content="eltOnly" model="closed" >
          <attribute type="fdt:nodeId"
  required="no" />
          <element type="AssemblyMember"   minOccurs="0" maxOccurs="*" />
     </ElementType>
     <ElementType name="ServiceSet" content="eltOnly" model="closed" >
          <attribute type="fdt:nodeId"
  required="no" />
          <element type="cip:Service"   minOccurs="1" maxOccurs="*" />
     </ElementType>
     <ElementType name="FDTChannel" content="eltOnly" model="closed" order="seq" >
          <attribute type="fdt:nodeId"
  required="no" />
          <attribute type="fdt:tag"   required="yes" />
          <attribute type="fdt:id"   required="yes" />
          <attribute type="protectedByChannelAssignment"   required="yes" />
          <attribute type="fdt:dataType"   required="yes" />
          <attribute type="assemblySize"   required="yes" />
          <attribute type="fdt:signalType"   required="yes" />
          <attribute type="frameApplicationTag"   required="no" />
          <attribute type="helpMessage"   required="no" />
          <element type="ServiceSet"   minOccurs="1" maxOccurs="1" />
          <element type="cip:CIPObjectAddress"   minOccurs="1" maxOccurs="1" />
          <element type="AssemblyMembers"   minOccurs="0" maxOccurs="1" />
           <!-- should be used if the data type is structured -->
     </ElementType>
     <ElementType name="FDTChannelType" content="eltOnly" model="closed" >
          <attribute type="fdt:nodeId"
  required="no" />
          <attribute type="gatewayBusCategory"   required="no" />
          <element type="fdt:VersionInformation"   minOccurs="1" maxOccurs="1" />
     </ElementType>
     <ElementType name="FDT" content="eltOnly" model="closed" >
          <attribute type="fdt:nodeId"
  required="no" />
          <element type="FDTChannelType"   minOccurs="1" maxOccurs="1" />
          <element type="FDTChannel"   minOccurs="1" maxOccurs="1" />
     </ElementType>
</Schema>

© by M&M Software GmbH, parts of this website taken from FDT Interface Specification Version 1.2.1, © by FDT Group, AISBL.
This website is published for support of M&M products as granted in license conditions, chapter 2.1.
Last updated 2015-02-05 15:17
Email: FDT Technical Support Line.