<Schema name="DTMModbusDeviceSchema"   xmlns="urn:schemas-microsoft-com:xml-data" xmlns:fdt="x-schema:FDTDataTypesSchema.xml" xmlns:dt="urn:schemas-microsoft-com:datatypes" xmlns:mb="x-schema:FDTModbusAddressSchema.xml" >
      <!-- FDT V1.2 device schema for Modbus protocol V1.0 -->
      <!-- The FDT DTMModbusDevice schema defines the mapping of the Modbus identification objects -->
      <!-- to standard FDT identification elements for FDT V1.2 -->
      <!-- The Modbus identification objects can be read with the standard Modbus service ReadDeviceIdentification -->
      <!-- Definition of general Fdt attributes -->
     <AttributeType name="schemaVersion" dt:type="number" default="1.0" />
      <!-- Definition of general FDT elements which contain the information about the applied protocol -->
      <!-- and the version of the protocol -->
     <AttributeType name="protocolName"
dt:type="string" default="protocol_Modbus" />
      <!-- The mapping of Modbus identification objects to FDT identification elements is divided into two categories: -->
      <!-- - Basic category: -->
      <!-- Mapping of mandatory Modbus identification objects to required (mandatory) FDT identification elements -->
      <!-- Modbus identification object VendorName -->
     <AttributeType name="vendorName"
dt:type="string" />
      <!-- Modbus identification object ProductCode -->
     <AttributeType name="productCode"
dt:type="string" />
      <!-- Modbus identification object MajorMinorRevision -->
     <AttributeType name="majorMinorRevision"
dt:type="string" />
      <!-- - Regular category: -->
      <!-- Mapping of optional Modbus identification objects to the optional FDT identification element IdValue -->
     <AttributeType name="name"
dt:type="enumeration" dt:values="ProductName ModelName VendorURL UserApplicationName" />
     <AttributeType name="protocolSpecificName"
dt:type="enumeration" dt:values="ProductName ModelName VendorURL UserApplicationName" />
     <AttributeType name="value"
dt:type="string" />
      <!-- Basic category: -->
      <!-- Mapping of Modbus identification elements required by the FDT DTMDeviceTypeIdent schema -->
      <!-- These elements represent all mandatory objects for Modbus device identification (basic category) -->
      <!-- Modbus identification object VendorName is mapped to FDT element IdManufacturer -->
     <ElementType name="IdManufacturer"
content="empty" model="closed" >
          <attribute type="vendorName"
  required="yes" />
     </ElementType>
      <!-- Modbus identification object ProductCode is mapped to FDT element IdTypeID -->
     <ElementType name="IdTypeID" content="empty" model="closed" >
          <attribute type="productCode"
  required="yes" />
     </ElementType>
      <!-- Modbus identification object MajorMinorRevision is mapped to FDT element IdSoftwareRevision -->
     <ElementType name="IdSoftwareRevision" content="empty" model="closed" >
          <attribute type="majorMinorRevision"
  required="yes" />
     </ElementType>
      <!-- Definition Modbus identification element not mandatory by the FDT DTMDeviceTypeIdent schema -->
      <!-- This element represent all objects for Modbus device identification (regular category) -->
     <ElementType name="IdValue" content="empty" model="closed" >
          <attribute type="name"
  required="yes" />
          <attribute type="value"   required="yes" />
          <attribute type="protocolSpecificName"   required="yes" />
     </ElementType>
     <ElementType name="IdValues" content="eltOnly" model="closed" >
          <element type="IdValue"
  minOccurs="0" maxOccurs="*" />
     </ElementType>
     <ElementType name="ModbusDevice" content="eltOnly" model="closed" >
          <attribute type="fdt:nodeId"
  required="no" />
          <attribute type="schemaVersion"   required="no" />
          <attribute type="protocolName"   required="yes" />
           <!-- Address information for Modbus TCP and Modbus Serial Line Devices -->
          <group order="one" maxOccurs="1" minOccurs="1" >
               <element type="mb:ModbusSerial"   />
               <element type="mb:ModbusTCP"   />
          </group>
          <element type="IdManufacturer"   minOccurs="1" maxOccurs="1" />
          <element type="IdTypeID"   minOccurs="1" maxOccurs="1" />
          <element type="IdSoftwareRevision"   minOccurs="1" maxOccurs="1" />
          <element type="IdValues"   minOccurs="0" maxOccurs="1" />
     </ElementType>
</Schema>