M&M FDT 1.2.1 Online Specification
 4.10.7.6 Topology Import-/Export


Interfaces and Methods   -   Schemas   -   FDT Specification   -   Quicklinks   -   Abbreviations

Up to 4 FDT Interface Specification

4.10.7.1 Redundancy Scenarios
4.10.7.2 Redundancy Support in Frame Application
4.10.7.3 Parent Component for Redundant Fieldbus
4.10.7.4 Redundancy Support in Device-DTM
4.10.7.5 Scan and Redundant Slaves
4.10.7.6 Topology Import-/Export

4.10.7.6 Topology Import-/Export

A Frame Application not aware of DTMs handling redundant slaves is not able to provide redundancy information within a FDT topology export file.

A Frame Application aware of DTMs handling redundant slaves can only add a DTMNode element at ChannelNodes if the appropriate DTM instance has not been added to topology by a IDtmRedundancy::OnAddedRedundantChild() event call. Instead the appropriate DTM element of the topology document should contain a BusInformation element containing the redundant address information.



© by M&M Software GmbH, parts of this website taken from FDT Interface Specification Version 1.2.1, © by FDT Group, AISBL.
This website is published for support of M&M products as granted in license conditions, chapter 2.1.
Last updated 2015-02-05 15:17
Email: FDT Technical Support Line.