M&M FDT 1.2.1 Online Specification
 IFdtActiveX::CloseActiveXControlRequest() method information


Interfaces and Methods   -   Schemas   -   FDT Specification   -   Quicklinks   -   Abbreviations

4.9.5.1 IFdtActiveX::CloseActiveXControlRequest()


This method can be called in the states:              

HRESULT CloseActiveXControlRequest (
[in] FdtUUIDString invokeId,
[out, retval] VARIANT_BOOL* result
);


Description:
A DTM sends a request to close one of its ActiveX controls.

Parameters:
invokeIdIdentifier for the started ActiveX control.


Return Value:
resultTRUE The ActiveX control will be released by the Frame Application FALSE The operation failed.


Behavior:
This method is used by a DTM if it wants to close an ActiveX user interface which was instantiated and embedded by the Frame Application. The Frame Application will release the link between the user interface and the DTM via IDtmActiveXControl::PrepareToRelease().

Comments:
-/-




© by M&M Software GmbH, parts of this website taken from FDT Interface Specification Version 1.2.1, © by FDT Group, AISBL.
This website is published for support of M&M products as granted in license conditions, chapter 2.1.
Last updated 2015-02-05 15:17
Email: FDT Technical Support Line.